Signal-10 General
In spite of functions and features implemented in the standalone mode (listed above), in cooperation
with the network controller the Signal-10:
¾ Monitors up to 10 fire alarm loops
o Of non-addressable types, namely:
Smoke Two Threshold Alarm Loop (with recognizing responses from one or two
detectors within the alarm loop), Type 1;
Combined Fire Single Threshold Alarm Loop (both smoke and heat fire detectors can be
brought in the alarm loop), Type 2;
Heat Two Threshold Alarm Loop, Type 3;
o or/and Fire Threshold Addressable Alarm Loops of the Type 14 each of which can monitor
up to 10 connected detectors such as DIP-34PA, S2000-IP-PA, and IPR 513-3PA;
¾ Transmits to the Orion system messages about such events as changing states of alarm
loops, attempts to arm / disarm alarm loops, accidental conditions, troubles of the alarm loops,
the relay outputs, power and so on;
¾ Supports centralized control of its outputs, that control being caused by events in the Orion
system, such as alarms in intrusion partitions, granting /rejecting access through access points
etc.;
¾ Supports arming / disarming its alarm loops by means of electronic credentials (iButtons or
cards) via any reader in the system;
¾ Supports arming / disarming its alarm loops by means of system push-button keypads or from
the network controller;
¾ Being requested by the network controller, translates the current values of resistance of the
alarm loops with connected detectors and initiating devices;
¾ Stores in its non-volatile memory up to 512 events which cannot be translated to the network
controller in case of a temporal communication loss.
Arming/disarming of alarm loops is implemented by using electronic keys which can be Dallas
iButtons (Touch Memory devices) or other identifiers with 1-Wire (µ-LAN) output interface. To read
electronic keys an external reader is to be connected to the relevant input of the Signal-10. The de-
vice provides indication of current partition conditions and results of requested operations by means
of two-color reader LED.
The keys have to be pre-programmed, that is enrolled either into the device memory (if alarm loops of
the device are armed/disarmed locally) or into the network database (under centralized control) along
with the rights to arm/disarms the particular loops of the device assigned to each key.